¿Necesita ayuda rápida? Llamada 1-800-LEE-PLUG

Microhidráulica Industrial

Reference Table

FLUID Bref ?? FLASH
POINT
POUR
POINT
Units psi ΔV/V/°F °F, min. °F, max.
Gasoline 150,000 0.00072 -50° -75°
JP-4 200,000 0.00057 -76°
MIL-H-5606 260,000 0.00046 200° -75°
MIL-H-83282 300,000 0.00046 400° -65°
MIL-H-6083 260,000 0.00044 200° -75°
SKYDROL 500B-4 340,000 0.00047 340° -80°
Silicone 100cs 150,000 0.00054 575° -65°
Water 310,000 0.00021 +32°

 

Bref. = Tangent adiabatic bulk modulus psi stated at 100°F, 2500 psi and no entrained air. A reference point.
?? = Coefficient of cubical thermal expansion/°F at 100°F
ΔP = Pressure rise, psi
ΔT = Temperature rise, °F
P1, P2 = Initial and final pressures, psi

*Flash point is the lowest temperature at which sufficient combustible vapor is driven off a fuel to flash when ignited in the presence of air.

FLUID Bref ?? FLASH
POINT
POUR
POINT
Units psi ΔV/V/°F °F, min. °F, max.
Gasoline 150,000 0.00072 -50° -75°
JP-4 200,000 0.00057 -76°
MIL-H-5606 260,000 0.00046 200° -75°
MIL-H-83282 300,000 0.00046 400° -65°
MIL-H-6083 260,000 0.00044 200° -75°
SKYDROL 500B-4 340,000 0.00047 340° -80°
Silicone 100cs 150,000 0.00054 575° -65°
Water 310,000 0.00021 +32°

 

Bref. = Tangent adiabatic bulk modulus psi stated at 100°F, 2500 psi and no entrained air. A reference point.
?? = Coefficient of cubical thermal expansion/°F at 100°F
ΔP = Pressure rise, psi
ΔT = Temperature rise, °F
P1, P2 = Initial and final pressures, psi

*Flash point is the lowest temperature at which sufficient combustible vapor is driven off a fuel to flash when ignited in the presence of air.